| Model No.︰ | FMF |
| Brand Name︰ | Sunshine |
| Country of Origin︰ | China |
| Unit Price︰ | - |
| Minimum Order︰ | - |
|
|
|
|
|
■
Features:
■Single or Twins Ultrasound transducer
■Data Graph and Trend Table Review of both mother and fetal
■Built-in thermal printer,
■Programmable alarms
■All the colors and looks or the parameters can be customsized
■Multi-face views, select focus on mother or fetal
■Storage of patient information and data
Performance Specifications:
■Display:8.4" Color TFT
■Resolution:640x480
■Display Mode:Standard View,Fetal View,Mother View
■Indicator:Power indicator light, Alarm sound
■Interface:Socket for connecting fetal's FHR, TOCO, and Fetal Movement sensorSocket for connecting mother's ECG, NIBP and SPO2 sensor.Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware.
■Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA
■Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
■Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
■Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
■User Configuration:All the color of parameters and waves can be set according to user's willing.
Technical specifications:
■Safety
■Meet the requirment of IEC60601 series
■Type of Protection:Class II with internal electirc power supply
■Degree of Protection:BF
■Dimention and Weight
■Dimention:92(W)x82(H)x22(D)mm
■Weight:136g(with battery)
■Operation Environment:
■Temperature:0℃~ +40℃
■Humidity:15% ~ 95%
■Storage Environment:
■Temperature:-20℃~ +60℃
■Humidity:10% ~ 95%
■Patient Range:Pregnant Adult
FHR:
■Ultrasound Frequency:2MHz
■Range:50 ~ 210 bpm
■Resolution:1bmp
■Accuracy:±2bmp
TOCO:
■Range:0 ~ 100%
■Resolution:1%
■Non-linear Error:<=±8%
■Zero control:Manual
FETAL MOVEMENT:
■Manual fetal movement mark
SPO2:
■Measurement Range:0 ~ 100%
■Resolution:1%
■Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
■Alarm Range:0% ~ 100%
■Refreshing Rate:1s
Pulse Rate:
■Measurement Range:25 ~ 250 bpm
■Resolution:1bpm
■Accuracy:±3 bpm (non-motion)
■Alarm Range:25 ~ 250 bmp
■Refreshing Rate:1s
ECG:
■Lead mode:3-lead or 5-lead
■Lead selection:I, II, III, AVR, AVL, AVF, V
■HR range:15 ~ 300 bpm
■ECG Waveform:2 channals
■Accuracy:±2bpm or ±2%, which is greater
■S-T segment detection range: -2.0mv ~ +2.0mv
■Arrhythmia analysis: 13 kinds of arrhythmia
■Alarm Range:15 ~ 300 bpm
NIBP:
■Method:Oscillometry
■Mode:Manual/Auto/Contiuous
■Measurement Range:25 ~ 260mmHg
■Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
■Resolution:1mmHg
■Overpressure Protection: 300mmHg
■Alarm range:25 ~260mmHg
Built-in Network capability for connect with central monitoring software |
|
|
|
|
|
|
|