Home Hot Product Medical Equip. Beauty Machine Ti Ophthalmic Ti. Surgical After Service Contact Us
Mammography & X Ray Series
Dental
Autoclave & Sterilizer
Transcranial Doppler
Lab Equipment
Anesthesia & Ventilator
Ultrasound
Hospital Bed
Infant Incubator,warmer,phototheropy
Suction & Stomach washing
Monitor,Fetal doppler,Oximeter,ECG
Colposcope
O.T Table & Light
Syringe & Infusion Pump
Injector for MR, CT etc.
Capsule endoscope system
Brain-Edema Machine
Andrologic & Gynecology series
Infection & Digestive Disease
Internal secretion & nephrosis
Titanium  Ophthalmic
Product Catalog 
 
Product Catalog > Anesthesia & Ventilator
Ventilator
Ventilator
Model No.︰3020
Brand Name︰-
Country of Origin︰China
Unit Price︰-
Minimum Order︰-

 Total 18 Related Items 
Prev45678Next
Auto next page:   SecondsPlay

Product Description

Main Feature:

Electronical control and pneumatic control
PEEP ventilator function

End-inspiratory hold(EIP,End-inspiratory stop) function

SIGH function
I:E function
All the parameters display on the broad
Simple to operate
Safe alarm and protection function

Main specification:

Ventilation Mode

   ----IPPV
   ----SIPPV(auxiliary/control ventilation)
   ----SIMV
   ----IPPV+SIGH
   ----SPONT
   ----PEEP/CPAP

  Adjustable ventilation parameter

   ----Frequency
   ----Inspiratory time
   ----Holding time
   ----Inspiratory trigger pressure
   ----Sigh time

  Monitoring parameter

   ----Tidal volume
   ----Minitoring parameter
   ----Frequency
   ----Inspiratory time
   ----Airway pressure

  Basic ventilation parameter

   ----Tidal volume:                0.08~1.5L
   ----Frequency:                   6~60/min (SIMV:1~12/min)
   ----Inspiratory time:            0.5~6s(I:E ratio:2:1~1:5)
   ----Holding time:                0~2s(≤50% of inspiratory time)
   ----Inspiratory trigger pressure:-2.0~+2.0KPa
   ----Sigh times:                  1~5time/100time
   ----PEEP:                        0~1.2kPa
   ----Mini oxygen concentration:   <45%
   ----Max safe pressure:           ≤6KPa

  Safe alarm

   ----No tidal volume
   ----Ventilation volume is too high(too low)
   ----Airway pressure is too high(too low)
   ----Frequency is too high 

Product Image
Ventilator
Related Products
MHJ-IIIB Anaesthesia Machine
MHJ-IIIB Anaesthesia Machine
MHJ-IIIB1 anaesthesia machine
MHJ-IIIB1 anaesthesia machine
MHJ- IIIB2 multifunction anaesthesia machine
MHJ- IIIB2 multifunction anaesthesia machine
MHJ- IIIB3 multifunction anaesthesia machine
MHJ- IIIB3 multifunction anaesthesia machine

Home  |  Hot Product  |  Medical Equip.  |  Beauty Machine  |  Ti Ophthalmic  |  Ti. Surgical  |  After Service  |  Contact Us  |  Sitemap
Powered by DIYTrade.com
HomeContact UsSitemap