Patient Monitor CE Marked

  • Patient Monitor CE Marked
  • Patient Monitor CE Marked
Model No.︰SSM9000D
Brand Name︰SunShineMed
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Share on:

 Total 29 Related Items 
Prev89101112Next

Product Description
15" color TFT screen
Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available.
Supporting wire or wireless network.

Technical Specifications
ECG
Lead mode 5 Leads, I, II, III, AVR, AVL, AVF, V
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
Heart rate Measure range:
Adult 15 ~ 300 bpm
Neonatal/Pediatric 15 ~ 350 bpm
Accuracy 1%
Resolution 1 bpm
Sensitivity > 200 V P-P
Differential Input Impedance > 5 M ohm
CMRR Monitor Mode >100 dB
Surgery Mode >100 dB
Diagnostic Mode >90 dB
Electrode offset potential 300mV
Leakage Current < 10 A
PACE pulse detect range 2 700mV
width 0.1 2ms
rise time 10 100 s
PACE pulse rejection range 2 700mV
width 0.1 2ms
rise time 10 100 s
Baseline Recovery < 3 s After defibrillation.
Signal Range 8 mV p-p
Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Calibration Signal 1 mV p-p, 5% accuracy
ST measurement Range -2.0 ~ +2.0 mV
Accuracy-0.8mV +0.8mV:
0.02mV or 10%, which is greater
Other range: unspecified

Respiration
Method Impedance between RA-LL
Differential Input Impedance >2.5 M
Respiration Impedance Range 0.3~3
Base Impedance Range 200 -4000
Bandwidth 0.3 ~ 2.5 Hz
Gain 0.25, 0.500, 1, 2, 4
Respiration Rate Measurement Range
Adult 0 ~ 120 BrPM
Neonatal / Pediatric 0 ~ 150 BrPM
Resolution 1 BrPM
Accuracy 0 6 BrPM: unspecified
7 150 BrPM: 2 BrPM or 2%,
use the greater
Inspiriting current < 300 A RMS max
Apnea Alarm 10 ~ 40 s

NIBP
Method Oscillometry
Measure mode Manual, Auto, STAT
Measure Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,
120,180,240,480 min
Measure Period in STAT Mode 5 min
Pulse Rate Range 40 ~ 240 bpm
Measure and Alarm Range Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 220 mmHg
MEAN20 ~ 240 mmHg
Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN20 ~ 170 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Static pressure accuracy 3mmHg
Resolution 1mmHg
Accuracy Maximum Mean error 5mmHg
Maximum Standard deviation 8mmHg
Overpressure Protection Adult 300 mmHg
Pediatric 240 mmHg
Neonatal 150 mmHg

SpO2
esolution 1 %
Accuracy 70% ~ 100% 2 %
40% ~ 69% 3 %
0% ~ 39% unspecified
Pulse Rate Measure and Alarm Range 20~300bpm
Resolution 1bpm
Accuracy 3bpm

TEMP
Channel 1
Measure and Alarm Range 0 ~ 50
Resolution 0.1
Accuracy(no sensor) 0.1 (25 45 ) , 0.2 (other)
Accuracy(include sensor) 0.2 32 - 42
0.3 other

Standard
Optional
: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
: EtCO2, IBP, Thermal Recorder
Product Image



Related Products
Defibrillator
Defibrillator
Defibrillator with a monitor
Defibrillator with a monitor
Portable Defibrillator with monitor
Portable Defibrillator with monitor
Defibrillator with a monitor
Defibrillator with a monitor