Patient Monitor CE Marked

  • Patient Monitor CE Marked
  • Patient Monitor CE Marked
  • Patient Monitor CE Marked
Model No.︰SSM9000C
Brand Name︰SunShineMed
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Share on:

 Total 29 Related Items 
Prev910111213Next

Product Description
12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available.
Supporting wire or wireless network.


Technical Specifications

ECG
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Wavef orm 2 c h
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Wavef orm 1 c h
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,
20mm/mV, auto
HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy 1% or 1bpm, which is greater
Resolution 1 bpm
Sensitivity > 200 (uVp-p)
Differential Input Impedance > 5 M
CMRR Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential 300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range 8 m V ( Vp-p )
Bandwidth Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 (mVp-p), Accuracy 5%
ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET,
BIGEMINY, TRIGEMINY, R ON T, VT>2,
PVC, TACHY, BRADY, MISSED BEATS,
PNP, PNC
Alarm Available
Review Available

Respiration
Differential Input Impedance >2.5 M
Measuring Impedance Range 0.3~5.0
Base line Impedance Range 0 ~2.5 K
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy 2 rpm
Apnea Alarm 10 ~ 40 S

NIBP
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution 1mmHg
Accuracy Maximum Mean error 5mmHg
Maximum Standard deviation 8mmHg
Overpressure Protection Adult Mode 297 3 mmHg
Pediatric Mode 240 3 mmHg
Neonatal Mode 147 3 mmHg

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization intervalabout 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate Measuring and Alarm Range 0~254bpm
Resolution 1bpm
Accuracy 2bpm

TEMP
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1C
Accuracy 0.1C
Actualization intervalabout 1 Sec.
Average Time Constant < 10 Sec.

IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP-10 ~ 40 mmHg
P1 / P2-10 ~ 300 mmHg
Press Sensor Sensitivity 5 uV/V/mmHg
Impedance 300-3000
Resolution 1 mmHg
Accuracy 2% or 1mmHg which is greater
Actualization interval about 1 secretary
Product Image




Related Products
Defibrillator
Defibrillator
Defibrillator with a monitor
Defibrillator with a monitor
Portable Defibrillator with monitor
Portable Defibrillator with monitor
Defibrillator with a monitor
Defibrillator with a monitor

Home  |  Product Catalog  |  Home Furniture  |  After Service  |  Contact Us  |  Sitemap  |  Mobile Version
Powered by DIYTrade.com
HomeContact UsSitemap